Emergency Exit Fire Doors (EI30–EI120)
Designed to hold back fire and smoke for a rated time, our doors feature smoke seals, EN 1125 panic bars and hydraulic door closers for fast, safe evacuation. Single- and double-leaf options suit stair cores, corridors and high-occupancy areas.
Selection Guide: Choose by Space & Occupancy
Specify doors by occupant load, clear opening and code objectives. Typical scenarios and recommendations:
| Scenario | Recommendation | Standard / Hardware | Note |
|---|---|---|---|
| Office / Public corridor | Single-leaf EI60 | EN 1125 panic bar, Sa/S200 smoke seals | Durable finish for high traffic |
| Shopping mall / Assembly area | Double-leaf EI90 | Coordinator kit, sync arm, closer (EN 1154) | Wider clear opening required |
| Stair core / Escape route | EI90–EI120 | Closer + automatic drop seal | Compatible with pressurised stairs |
| Industrial / Warehouse | EI60 steel door | Impact-resistant skin; guards | Consider forklift/vehicle traffic |
Construction, Materials & Hardware Options
Thickness and density vary by rating/model; the table summarises a typical configuration.
| Component | Material / Property | Function |
|---|---|---|
| Leaf | 1.0–1.5 mm galvanised steel, mineral wool core | EI fire resistance, rigidity |
| Frame | Steel frame with anchors | Robust fixing, smoke/flame barrier |
| Seals | Intumescent + smoke seals (Sa/S200) | Flame/smoke tightness |
| Hardware | EN 1125 panic bar, EN 1154 closer, EN 1155 magnet (opt.) | Safe egress and controlled closing |
| Finish | Polyester powder coat (RAL); scratch resistance | Aesthetics and durability |
Application, Installation & Details
- Hinge side opens towards the escape direction; keep clear width (single ≥ 80–90 cm, double ≥ 120 cm).
- Regularly verify closer settings (speed/latching); consider automatic drop seals where needed.
- For pressurised stairs, ensure Sa/S200 smoke seals and threshold solutions are compatible.
- Options: fire-rated glazing, external handle/escutcheon kit, kick plates, electromagnetic holders.
Standards & Compliance
Fire & Smoke
- EN 1634-1 (Fire resistance) — EI30/60/90/120
- EN 1634-3 (Smoke control) — Sa / S200
- EN 13501-2 classification (EI, S)
Hardware
- EN 1125 (Panic exit devices)
- EN 179 (Emergency exit devices for trained users)
- EN 1154 (Door closers), EN 1155 (Electromagnetic holders)
Maintenance, Functional Tests & Intervals
Door performance is maintained through periodic checks and records. Suggested intervals:
| Interval | Action | Description |
|---|---|---|
| Monthly | Visual inspection | Seals/hinges, panic bar and positive latching |
| Every 6 months | Functional test | Closer adjustment, holder/release scenario (if any) |
| Annually | Servicing | Smoke seals/ironmongery service; documentation update |
Frequently Asked Questions
Is a panic bar mandatory? ▾
In assembly and escape doors, EN 1125 panic devices are generally required. For doors used by trained staff only, EN 179 devices may be acceptable.
Do I need a threshold? ▾
For smoke control, use automatic drop seals or bottom seals. Where step-free access is required, consider ramped/automatic threshold solutions.